Common Mistakes During Fire Rated Door Installation

Because they inhibit the spread of smoke and fire, Fire-Rated Doors are essential to the protection of buildings and their occupants. Nevertheless, proper installation is crucial to their efficacy. If not fitted correctly, even the best fire-rated doors may not function as intended. The most frequent errors made when installing fire-rated doors are examined in this tutorial, along with their consequences and preventative measures.

 


Why Proper Fire Door Installation Matters

Doors with a fire rating are made to adhere to strict performance requirements. Properly installed, they can:

  1. Provide Safe Evacuation Time: Fire doors delay the spread of fire, giving occupants crucial time to evacuate.

  2. Prevent Fire Spread: Compartmentalising the building helps contain fire to its origin.

  3. Ensure Legal Compliance: Proper installation is essential to meet UK Building Regulations and avoid penalties.

However, improper installation undermines these benefits, risking lives, property, and legal compliance.


Common Mistakes During Fire Door Installation

Let’s delve into some of the most frequent errors encountered during fire-rated door installations and their repercussions.


1. Incorrect Door Frame Installation

The performance of a fire-rated door is based on the door frame. Among the frame installation errors are:

  1. Improper Alignment: Misaligned frames compromise the seal, allowing smoke and fire to penetrate.
  2. Inadequate Fixings: Insufficient screws or poor-quality fixings can lead to instability.
  3. Incorrect Frame Material: Non-compliant materials may not withstand fire.

The answer is to always use fire-rated door frames and make sure they are installed plumb, square, and level with the right fasteners in accordance with the manufacturer's instructions.


2. Improper Gaps Between the Door and Frame

The gap between the fire door and its frame is critical. Common mistakes include:

  1. Excessive Gaps: Large gaps allow smoke and fire to pass through.
  2. Inconsistent Gaps: Uneven spacing can lead to improper sealing.

According to UK rules, there should be a minimum of 10mm at the bottom and a maximum of 3mm along the top and sides (unless otherwise noted).

Solution: To guarantee uniform and compliance spacing during installation, use gap gauges.


3. Using Non-Certified Doors or Components

Using uncertified products is one of the most dangerous errors. In a fire, non-compliant doors or parts may fail too soon.

Examples include:

  • Hinges, locks, or seals that aren’t fire-rated.

  • Doors without proper certification marks.

Solution: Always verify that all components, including the door, frame, hinges, and seals, are certified and meet UK standards such as BS 476 or EN 1634-1.


4. Incorrect Installation of Fire Seals

Fire seals, or intumescent strips, expand under heat to close gaps. Mistakes with fire seals include:

  1. Incorrect Positioning: Seals are not installed correctly.
  2. Damaged Seals: Seals that were ripped, cut, or put incorrectly during installation.
  3. Completely Ignoring Seals: This crucial error renders the door ineffective.

Solution: Pay close attention to the manufacturer's recommendations about the condition and positioning of the seal.


5. Inadequate Door Hardware Installation

Fire-rated doors require specific hardware. Common issues include:

  1. Using Standard Hinges: Hinges that aren't fire-rated may melt or break.
  2. Incorrectly Fitted Closers: If door closers are not properly aligned, they may not be able to fully close the door.
  3. Inappropriate Locks: Performance may be hampered by locks that are not fire door rated.

Solution: Verify that all hardware, including as locks, hinges, and closers, is fitted in accordance with certification standards and is fire-rated.


6. Failing to Account for Door Weight

Fire-rated doors are typically heavier than standard doors. Neglecting this fact can lead to:

  1. Hinges that are not made to support the weight may fail due to strain.
  2. Door Sagging: Inadequate framing or hinges may eventually cause the door to droop, leaving gaps.

Solution: Make sure the frame can sustain the weight of the door and use strong, fire-rated hinges.


7. Inadequate Documentation and Certification

Every fire door installation must come with proper documentation. Mistakes include:

  1. Missing Certificates: Lack of certification for the door or components.
  2. Improper Label Placement: Certification labels removed or placed incorrectly.

Solution: Retain all documentation and ensure labels remain visible and intact for inspections.


8. Ignoring Manufacturer Instructions

Manufacturers provide specific instructions for installing their fire-rated doors. Ignoring these can lead to non-compliance and reduced performance.

Common Oversights:

  1. Fitting the door in an unapproved orientation.
  2. Using non-specified screws or fixings.

Solution: Follow the manufacturer’s guidelines strictly and seek clarification if needed.


9. Failure to Conduct Post-Installation Inspections

Ignoring post-installation inspections is a serious mistake. Problems like misaligned gaps, missing seals, or hardware that isn't installed correctly are frequently overlooked.

Solution: To guarantee adherence to fire safety regulations, carry out comprehensive inspections following installation.


10. Improper Modifications Post-Installation

A fire-rated door may lose its certification if unauthorised changes are made to it. Among the examples are:

  1. drilling more holes.
  2. cutting the door shorter than is permitted.
  3. adding hardware that isn't compliant.

Solution: Don't make any changes unless the manufacturer specifically authorises them.


The Role of Professionals in Fire Door Installation

Because installing a fire door is so important and complicated, it is imperative that certified professionals be involved. Certified installers guarantee compliance and safety by being aware of UK laws, product specifications, and industry best practices.


Tips for Ensuring Proper Installation

  1. Use Certified Installers: Engage professionals with recognised certifications such as those from FIRAS or BM TRADA.

  2. Verify Products: Ensure all components are certified and compliant with UK standards.

  3. Document Everything: Retain records of certifications, installation guidelines, and inspections.

  4. Regular Maintenance: Schedule periodic inspections to ensure continued compliance.

  5. Training and Awareness: Educate all stakeholders on the importance of proper fire-rated door installation.


Conclusion

An essential part of every building's fire protection plan is having fire-rated doors. However, correct installation is essential to their efficacy. Building owners and contractors can make sure that doors function as intended by avoiding typical errors, such as incorrect framing and skipping post-installation inspections.

Following fire safety regulations in the UK is a commitment to safeguarding people's lives and property, not just a matter of compliance. Achieving strong fire safety requires knowing these typical errors and how to fix them, whether you're a facility manager, contractor, or building owner.

For more information about our interior or exterior doors or door accessories, give us a call at 01603 622261 and speak to a member of our expert team today or Email us at sales@doorsuppliesonline.co.uk. We look forward to hearing from you.